1.       General scope

1-1 The specifications apply to the coreless cylindrical permanent magnetic micro vibration motor DC model Z6S00A010F.

2.       Operating conditions

Items

Specifications

Condition & Remarks

2-1

Rated voltage

1.3V DC

 

2-2

Rated load

Counter weight

As specified in the outline drawing.

2-3

Rotation

C.W. (clockwise)

 

2-4

Motor position

All positions

 

2-5

Operating voltage

0.9 ~ 1.6V DC

 

2-6

Operating conditions

-30 ~ 70°C, ordinary humidity

No condensation of moisture.

2-7

Storage conditions

-40 ~ 80°C, ordinary humidity

No condensation of moisture.

 

3.        Measuring conditions

Items

Specifications

Condition & Remarks

3-1

Temperature

20±2°C

 

3-2

Humidity

(63 ~ 67%) RH

 

3-3

Motor position

Motor shaft horizontal

Lock the motor in a test fixture.

3-4 All data are based on the measuring conditions: Temperature, 20°C; Humidity, 65% RH. If any disagreement occurs, such test conditions are available: Temperature, 5~35°C; Humidity, 45 ~ 85% RH.

4.       Mechanical specifications

Items

Specifications

Condition & Remarks

4-1

Configuration

As specified in outline drawing

Outline drawing No:Z6SCAA0061141

old number - Z6S00A010F.

4-2

Appearance

There shall be no evidence of mechanical damage and shall not have inadequate corrosion, etc.

Visual examination: Inspection carried out on samples.

4-3

Shaft end play

0.1 ~ 0.3mm

 

4-4

Weight of motor

2.52g approx.

Body + Vibration weight: 2.00+0.52.

4-5

Holding strength of vibration weight

49N (5kgf)

 

 

5.       Performance and characteristics

Items

Specifications

Condition & Remarks

5-1

Rated speed

8500±2000rpm

At rated voltage and rated load (vibration weight).

5-2

Rated current

80mA max

5-3

Stall current

140mA max

At rated voltage.

5-4

Starting voltage

0.75V DC max

At rated load (vibration weight) any position of rotor.

5-5

Insulation resistance

1MΩ min

At DC 100V between the lead wires and motor body.

5-6

Terminal resistance

11Ω approx.

At 20°C.

5-7

Mechanical noise

50db (A) max

 

Measured at rated voltage and rated load (vibration weight).

Background noise: 28db (A) max. @ 10cm.

Measuring instruments: B & K.

The weight of jig: 700g.

 

 

 

 

 

 

 

 

 

 

 

6.   Reliability Test

Items

Standard test conditions

Condition & Remarks

6-1

Life test

 

After 2 hours exposure in ordinary Motors shall be approved as specified in item 7-1.

Position

Horizontal

Horizontal

Voltage

Rated

Rated

Load

Vibe weight

Vibe weight

Temperature

20°C

40°C

Humidity

65%

90%

Life (cycles)

200,000

400,000

6-2

Low temperature exposure test

Temperature:    -40±2°C

Time:                            96hrs

After 2 hours exposure in ordinary Motors shall be approved as specified in item 7-2.

6-3

High temperature exposure test

Temperature:    60±2°C

Time:                            96hrs

6-4

High humidity exposure test

Temperature:    40±2°C

Humidity:                      90 ~ 95% RH

Exposure time: 240hrs

Dry time:                      4hrs

No condensation of moisture

6-5

Vibration test

Displacement:   1.5mm (p-p)

Frequency:       10 ~ 55Hz

Period:             20 Mins log sweep

                      (10 ~ 55 ~ 10Hz)

Direction:         x, y, z

Time:               Every 2 hours

After the test motors shall be approved as specified in item 7-2.

6-6

Drop test

Set the motor to the approximately 100g (include the motor) weight of block drop the motor on the concrete floor.

Height:              1.5 meters

Direction:          ±x, ±y, ±z

Times:               Twice Each  

After the test motors shall be approved as specified in item 7-2.

 

 

6-7

Heat stock test

Period: 32 cycles

Exposed at ordinary temperature and ordinary humidity for 24 hours before measurement.

After the test motors shall be approved as specified in item 7-2.

7.   Post environmental

Items

Requirements

7-1

Table A

1) Rated speed:                                    Initial data -30% min./ +60% max.

2) Rated current:                                   Initial data ±30% max

3) Insulation resistance: 1MΩ min

4) Starting voltage:                    1.1V DC max

5) Current waveform: Normal

7-2

Table B

1) Rated speed:                                    Initial data -30% min./ +60% max.

2) Rated current:                                   Initial data ±30% max

3) Starting voltage:                    1.1V DC max

8.   Matters to be paid attention to when using motor

8-1 Lay the motors carefully in transportation to avoid any damage to the motor body or its electric function because of collision.

8-2 Storage temperature 20°C±10°C. Do not leave the motors in the environment of high temperature, high humidity and gas that will cause rust and corrosion. Please don’t store the motors for over 6 months.

8-3 Do not lock the motor shaft when the electric power is supplied.

8-4 Do not touch the weights when motor is rotating.

 