VibratorMotor.com

VibratorMotor.com

Home     |     Product Info    |     About us     |     Factory tour     |    ISO Certifications    |    RoHS Info    |    Sample Request    |    Contact us   

 

Part No.    Z6DC1B0730091

           Click to Download PDF Format !

                                   

1.       General scope

1-1  This specification applies to cylindrical permanent magnetic DC vibration motor model  Z6DC1B0730091.

2.       Operating conditions

Items

Specifications

Condition & Remarks

2-1

Rated voltage

3.0V DC

 

2-2

Rated load

Counter weight

As specified in the outline drawing.

2-3

Rotation

C.W. (clockwise)

 

2-4

Motor position

All positions

 

2-5

Operating voltage

2.2 ~ 3.6V DC

 

2-6

Operating conditions

-30 ~ 70°C, ordinary humidity

No condensation of moisture.

2-7

Storage conditions

-40 ~ 80°C, ordinary humidity

No condensation of moisture.

 

3.        Measuring conditions

Items

Specifications

Condition & Remarks

3-1

Temperature

20±2°C

 

3-2

Humidity

(63 ~ 67%) RH

 

3-3

Motor position

Shaft horizontal

Lock the motor in a test fixture.

3-4   All data are based on the measurement under the temperature of 20 °C  and humidity 65 %RH. However, the ranges of temperature 5~35 °C  and humidity 45~85 %RH are to be applicable as long as no problems.

4.       Mechanical specifications

Items

Specifications

Condition & Remarks

4-1

Configuration

As specified in outline drawing

Outline drawing No: Z6DC1B0730091.

4-2

Appearance

There shall be no evidence of mechanical damage and shall not have inadequate corrosion and so on

Visual examination (allowable extent is based on boundary sample)

4-3

Shaft end play

0.1 ~ 0.3mm

 

4-4

Holding strength of vibration weight

49N (5kgf) min.

 

 

5.       Performance and characteristics

Items

Specifications

Condition & Remarks

5-1

Rated speed

6,500±2,000rpm

At rated voltage and rated load (vibration weight).

5-2

Rated current

90mA max

5-3

Stall current

125mA max

At rated voltage.

5-4

Starting voltage

1.7V DC max

At rated load (vibration weight) any position of rotor.

5-5

Insulation resistance

1MΩ min

At DC 100V between the lead wires and motor body.

5-6

Terminal resistance

30Ω approx. (±20%)

At 20°C.

5-7

Mechanical noise

50db (A) max

 

Measured at rated voltage and rated load (counterweight).

Background noise: 28db (A) max. @ 10cm.

Measuring instruments: B & K.

The weight of jig: 700g.

 

 

 

 

 

 

 

 

 

 

 

6.   Reliability Test

Items

Standard test conditions

Condition & Remarks

6-1

Life test

 

Position

Voltage

Load

Temperature

Humidity

Life

Horizontal

Rated

Counter weight

20 ºC

65 %

200,000 cycles

After 2 hours exposure in ordinary Motors shall be approved as specified in item 7-1.

6-2

Low Temp.

Temperature:       -40±2°C

Time:                    96hrs

After 2 hours exposure in ordinary Motors shall be approved as specified in item 7-2.

6-3

High Temp.

Temperature:        60±2°C

Time:                    96hrs

6-4

Humidity exposure

Temperature:        40±2°C

Humidity:              80 ~ 95% RH

Exposure time:      96hrs

No condensation of moisture

6-5

Vibration

Displacement:       1.5mm (p-p)

Frequency:           10 ~ 55Hz

Period:                 20 Mins log sweep (10 ~ 55 ~ 10Hz)

Direction:             x, y, z

Time:                   Every 2 hours

After the test motors shall be approved as specified in item 7-2.

6-6

Free fall

Test state: Set the motor to the approximately 75 g

(include the motor) weight of block drop the motor

on the concrete floor.

Height:                          1.5 m

Direction:                      ±x, ±y, ±z

Number of times:           Twice each

After the test motors shall be approved as specified in item 7-2.

6-7

Heat shock

Test cycle:                     5 cycles

After the test motors shall be approved as specified in item 7-2.

 

7.   Post environmental

Items

Requirements

7-1

Table A

1) Rated speed:                                    Initial data -30% min./ +60% max.

2) Rated current:                                   Initial data ±30% max

3) Insulation resistance:                         1MΩ min

4) Starting voltage:                                2.0 V DC max

7-2

Table B

1) Rated speed:                                    Initial data -30% min./ +60% max.

2) Rated current:                                  Initial data ±30% max

3) Starting voltage:                               2.0V DC max

8.   Matters to be paid attention to when using motor

8-1  Please lay the motors carefully in transportation to avoid any damage to the motor body or its electric function because of collision.

8-2  Please do not leave the motors in the environment of high temperature, high humidity and gas that will cause rust and corrosion. Please don’t store the motors for over 6 months.

8-3  Please do not lock the motor shaft when the electric power is supplied.

8-4  Please do not touch the weights when motor is rotating.

 

Home Product Info | About us  | Factory tour  | ISO Certifications  |  RoHS Info | Sample Request  |  Contact us

Copyright 2010  ©  VibratorMotor.com