1. General scope
1-1 The specification applies
to the cylindrical permanent-magnetic micro vibration motors
DC model
Z4TL2B0370649.
2. Operating conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
2-1
|
Rated voltage
|
3.0V
DC
|
|
|
2-2
|
Rated load
|
Counterweight
|
As specified in 10. Outline drawing |
|
2-3
|
Rotation |
C.W/C.C.W (clockwise
or counterwise)
|
|
|
2-4
|
Motor position
|
All positions
|
|
|
2-5 |
Operating voltage
|
2.2~3.6V DC |
|
|
2-6
|
Operating conditions
|
-30 ~ 70°C, ordinary humidity:65±20%RH |
No condensation of moisture.
|
|
2-7
|
Storage conditions
|
-30 ~ 80°C, ordinary humidity:65±20%RH |
No condensation of moisture. |
3. Measuring conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63% ~ 67%) RH
|
|
|
3-3
|
Motor position
|
Motor Shaft
horizontal
|
Lock the motor in a test fixture.
|
3-4 The measurement at 20 & 65%RH is standard. If the judgment is not
questionable, recognize measurement at 5 to 35 & relative humidity 45% to
85%. Direction of motor is shaft horizontal.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition & Remarks
|
|
4-1
|
Configuration
|
As specified 10. Outline Drawing
|
Outline drawing No: Z4TL2B0370649.
|
|
4-2
|
Appearance
|
There shall be no evidence of
mechanical damage and shall not have inadequate corrosion and so on |
Visual examination (allowable extent is based on boundary
sample) |
|
4-3
|
Shaft end play
|
0.05 mm ~ 0.2 mm |
|
|
4-4 |
Holding strength of vibration
weight
|
49N (5kgf)
Min |
|
5. Performance and characteristics
|
Items
|
Specifications
|
Condition & Remarks
|
|
5-1
|
Rated speed
|
10,000
±
2,000 rpm
|
At rated voltage and rated load
(vibration weight).
|
|
5-2
|
Rated current
|
30mA
max
|
|
5-3
|
Stall current
|
40mA
max
|
At rated voltage.
|
|
5-4
|
Starting voltage
|
2.4V
DC max
|
At rated load (vibration weight)
any position of rotor.
|
|
5-5
|
Insulation resistance
|
1MΩ min
|
At DC 100V between tTerminal and
case. |
|
5-6
|
Terminal resistance
|
93Ω
approx.
|
At 20°C.
|
|
5-7
|
Mechanical noise
|
50db (A) Max
|
|
|
At rated voltage and rated load (Counterweight).
Background noise: 28db (A) max. @ 10cm.
Measuring instruments: B & K.
The weight of jig: 700g.
|
|

|
6. Reliability Test
|
Items
|
Standard test
conditions |
Condition &
Remarks |
|
6-1 |
Life time |

|
After the test, motors
shall be approved as specified in item 7-1. |
|
Position |
Volt |
Load |
Temp |
Humi |
Life |
|
Horozon |
Rated |
Weight |
20°C |
65% |
Cycles |
|
6-2 |
Low temp exposure |
Temperature: -40±2°C
Time:
96h |
After the test motors
shall be approved as specified in item 7-2. |
|
6-3 |
High temp exposure |
Temperature: 80±2°C
Time:
96hrs
|
|
6-4 |
High humidity exposure
test
|
Temperature:
40±2°C
Humidity:
90~95% RH
Exposure time: 96hrs
No condensation of
moisture
|
6-5
|
Vibration test
|
|
|
Frequency: 10~55~10 Hz
Displacement: 1.5 mm (p-p)
Acceleration: 22m/s²
Condition: 20/Vibration
20 minutes along x. y. z. direction, under normal package.
|
After the test motors
shall be approved as specified in item 7-2. |
|
6-6
|
Free fall |
|
Set the motor to the approximately
100g (include the motor) weight of block drop the motor on the concrete
floor.
Height: 1.5 meters
Direction: ±x, ±y, ±z
Number of Times: Twice
2 each |
After the test motors
shall be approved as specified in item 7-2. |
|
|
6-7
|
Heat stock test
|
Period: 32 cycles
Exposed at ordinary
temperature and ordinary humidity for 24 hours before measurement.
|
After 2 hours exposure in ordinary temperature and
humidity, Motors shall be approved as specified in item 7-2. |
7. Requirements
|
Items |
Requirements
|
|
7-1
|
Table A
|
1) Rated
speed:
Initial data -30% min./
Initial data
+60% Max
2) Rated
current: ±30%
Initial data
±30%
max
3) Starting
voltage:
2.8V DC Max
|
|
7-2
|
Table B
|
1) Rated
speed:
±30%
Initial data
±30%
max
2) Rated
current:
±30%
Initial data ±30%
max
3) Starting
voltage: 2.8 V DC
Max |
|
8.
Caution and Matters
8-1
(Please lay the motors carefully in transportation to avoid any serious
damage to the motor body or its electric function because of collision.)
8-2
(Please use and storage motors according to N0.2 item
(Operating Conditions) in specification, or else motor characteristics would
be affected.)
8-3
(Make arrangement to limit the storage period to 6 months
or less. Condensation of atmosphere must be avoided in motor usage or
opening the packaging of the motor.)
8-4 (For proper operation. storage and operating environment must not
contain corrosive gases. For example H2S. SO2. NO2. CL2. etc. In addition
storage environment must not have materials that emit corrosive gases
especially from silicon. cyanic. formalin and phenol group. In the mechanism
or the set.
existence of corrosive gases may cause no rotation in motor.)
8-5 (Please don't stall the shaft for a long time after powering, and
not to touch the weight when motor is rotating.)
8-6 (There should be no sundries
(such as grain, fibre, hair, small tape, glue etc.) in the shaft end play.)
|
|