Home | Product Info | About us | Factory tour | ISO Certifications | RoHS Info | Sample Request | Contact us |
|||
|
Part No. Z4TL2B0370649 |
1. General scope
1-1 The specification applies to the cylindrical permanent-magnetic micro vibration motors DC model Z4TL2B0370649.
2. Operating conditions
|
Items |
Specifications |
Condition & Remarks |
|
|
2-1 |
Rated voltage |
3.0V
DC |
|
|
2-2 |
Rated load |
Counterweight |
As specified in 10. Outline drawing |
|
2-3 |
Rotation |
C.W/C.C.W
(clockwise or counterwise) |
|
|
2-4 |
Motor position |
All positions |
|
|
2-5 |
Operating voltage |
2.2~3.6V DC |
|
|
2-6 |
Operating conditions |
-30 ~ 70°C, ordinary humidity:65±20%RH |
No condensation of moisture. |
|
2-7 |
Storage conditions |
-30 ~ 80°C, ordinary humidity:65±20%RH |
No condensation of moisture. |
3. Measuring conditions
|
Items |
Specifications |
Condition & Remarks |
|
|
3-1 |
Temperature |
20±2°C |
|
|
3-2 |
Humidity |
(63% ~ 67%) RH |
|
|
3-3 |
Motor position |
Motor Shaft
horizontal |
Lock the motor in a test fixture. |
3-4 The measurement at 20 & 65%RH is standard. If the judgment is not questionable, recognize measurement at 5 to 35 & relative humidity 45% to 85%. Direction of motor is shaft horizontal.
4. Mechanical specifications
|
Items |
Specifications |
Condition & Remarks |
|
|
4-1 |
Configuration |
As specified 10. Outline Drawing |
Outline drawing No: Z4TL2B0370649. |
|
4-2 |
Appearance |
There shall be no evidence of |
Visual examination (allowable extent is based on boundary sample) |
|
4-3 |
Shaft end play |
0.05 mm ~ 0.2 mm |
|
|
4-4 |
Holding strength of vibration weight |
49N (5kgf) |
|
5. Performance and characteristics
|
Items |
Specifications |
Condition & Remarks |
|
|
5-1 |
Rated speed |
10,000
±
2,000 rpm |
At rated voltage and rated load
(vibration weight). |
|
5-2 |
Rated current |
30mA
max |
|
|
5-3 |
Stall current |
40mA
max |
At rated voltage. |
|
5-4 |
Starting voltage |
2.4V
DC max |
At rated load (vibration weight) any
position of rotor. |
|
5-5 |
Insulation resistance |
1MΩ min |
At DC 100V between tTerminal and case. |
|
5-6 |
Terminal resistance |
93Ω approx. |
At 20°C. |
|
5-7 |
Mechanical noise |
50db (A) Max |
|
|
At rated voltage and rated load (Counterweight).
Background noise: 28db (A) max. @ 10cm.
Measuring instruments: B & K. The weight of jig: 700g.
|
|||
|
|
|||
6. Reliability Test
|
Items |
Standard test conditions |
Condition & Remarks |
|||||||||||||
|
6-1 |
Life time |
|
After the test, motors shall be approved as specified in item 7-1. |
||||||||||||
|
6-2 |
Low temp exposure |
Temperature: -40±2°C Time: 96h |
After the test motors shall be approved as specified in item 7-2. |
||||||||||||
| 6-3 | High temp exposure |
Temperature: 80±2°C Time: 96hrs |
|||||||||||||
| 6-4 | High humidity exposure test |
Temperature:
40±2°C Humidity: 90~95% RH Exposure time: 96hrs No condensation of moisture |
|||||||||||||
|
6-5 |
Vibration test |
||||||||||||||
|
After the test motors shall be approved as specified in item 7-2. |
|||||||||||||||
|
6-6 |
Free fall | ||||||||||||||
|
Set the motor to the approximately 100g (include the motor) weight of block drop the motor on the concrete floor. Height: 1.5 meters Direction: ±x, ±y, ±z Number of Times: Twice 2 each |
After the test motors shall be approved as specified in item 7-2. |
||||||||||||||
|
6-7 |
Heat stock test |
Period: 32 cycles Exposed at ordinary temperature and ordinary humidity for 24 hours before measurement. |
After 2 hours exposure in ordinary temperature and humidity, Motors shall be approved as specified in item 7-2. |
7. Requirements
|
Items |
Requirements |
|
|
7-1 |
Table A |
1) Rated speed: Initial data -30% min./ Initial data +60% Max 2) Rated current: ±30% Initial data ±30% max 3) Starting voltage: 2.8V DC Max |
|
7-2 |
Table B |
1) Rated speed: ±30% Initial data ±30% max 2) Rated current: ±30% Initial data ±30% max 3) Starting voltage: 2.8 V DC Max |
|
8.
Caution and Matters 8-1 (Please lay the motors carefully in transportation to avoid any serious damage to the motor body or its electric function because of collision.) 8-2 (Please use and storage motors according to N0.2 item (Operating Conditions) in specification, or else motor characteristics would be affected.) 8-3 (Make arrangement to limit the storage period to 6 months or less. Condensation of atmosphere must be avoided in motor usage or opening the packaging of the motor.)
8-4 (For proper operation. storage and operating
environment must not contain corrosive gases. For example H2S. SO2. NO2.
CL2. etc. In addition storage environment must not have materials that emit
corrosive gases especially from silicon. cyanic. formalin and phenol group.
In the mechanism or the set. 8-5 (Please don't stall the shaft for a long time after powering, and not to touch the weight when motor is rotating.)
8-6 (There should be no sundries
(such as grain, fibre, hair, small tape, glue etc.) in the shaft end play.) |
|
Home | Product Info | About us | Factory tour | ISO Certifications | RoHS Info | Sample Request | Contact us |