1. General
scope
1-1
The specifications apply
to the coreless cylindrical permanent magnetic micro
vibration motor
DC model
Z4TH7B0340804.
2. Operating
conditions
|
Items
|
Specifications
|
Condition
& Remarks
|
|
2-1
|
Rated voltage
|
3.0V
DC
|
|
|
2-2
|
Rated load
|
Counter
weight
|
As specified
in the outline drawing.
|
|
2-3 |
Rated speed |
11,000 ±
2,500 rpm |
|
|
2-4
|
Rotation |
C.W. (clockwise)
|
|
|
2-5
|
Motor
position
|
All positions
|
|
|
2-6 |
Operating
voltage
|
2.2~3.6V DC
|
|
|
2-7
|
Operating
conditions
|
-30 ~ 70°C,
ordinary humidity
|
No
condensation of moisture.
|
|
2-8
|
Storage
conditions
|
-40 ~ 80°C,
ordinary humidity
|
No condensation of
moisture. |
3. Measuring
conditions
|
Items
|
Specifications
|
Condition
& Remarks
|
|
3-1
|
Temperature
|
10±35°C
|
|
|
3-2
|
Humidity
|
(45% ~ 75%)
RH
|
|
|
3-3
|
Motor
position
|
Shaft
horizontal
|
Lock the
motor in a test fixture.
|
3-4 All data are based on the measuring conditions:
Temperature, 20°C; Humidity, 65% RH. If any
disagreement occurs, such test conditions are
available: Temperature, 5~35°C; Humidity, 45 ~ 85% RH.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition
& Remarks
|
|
4-1
|
Configuration
|
As specified
in outline drawing
|
Outline drawing No:
Z4TH7B0340804.
|
|
4-2
|
Appearance
|
There shall
be no evidence of mechanical damage and shall not
have inadequate corrosion, etc.
|
Visual
examination: Inspection carried out on samples.
|
|
4-3
|
Shaft end
play
|
0.05 mm ~ 0.2 mm Max |
|
|
4-4
|
Weight of
motor
|
1.0±0.02g
approx.
|
|
|
4-5
|
Holding
strength of vibration weight
|
49N (5kgf)
|
|
5. Performance
and characteristics
|
Items
|
Specifications
|
Condition
& Remarks
|
|
5-1
|
Rated speed
|
11,000
±
2,500 rpm
|
At rated
voltage and rated load (vibration weight).
|
|
5-2
|
Rated current
|
100mA
max
|
|
5-3
|
Stall current
|
130mA
max
|
At rated
voltage.
|
|
5-4
|
Starting
voltage
|
2.0V
DC max
|
At rated load
(vibration weight) any position of rotor.
|
|
5-5
|
Insulation
resistance
|
1MΩ min
|
At DC 100V
between the lead wires and motor body.
|
|
5-6
|
Terminal
resistance
|
29Ω
approx.
|
At 20°C.
|
|
5-7
|
Mechanical
noise
|
45db (A) max
|
|
|
Measured at rated voltage and rated load
(vibration weight).
Background noise: 28db (A) max. @ 10cm.
Measuring instruments: B & K.
The weight of jig: 700g.
|
|

|
6.
Reliability Test
|
Items |
Standard test conditions |
Condition & Remarks |
|
6-1
|
Life
test |

|
After 2 hours exposure in ordinary Motors shall be
approved as specified in item 7-1. |
|
Position |
Voltage |
Load |
Temperature |
Humidity |
Life |
|
Horizontal |
Rated |
Counter weight |
20
ºC |
65
% |
200,000 cycles |
|
40
ºC |
9 0
% |
40,000 cycles |
|
|
6-2 |
Low
temperature exposure test |
Temperature: -40±2°C
Time: 96hrs
|
After the test motors shall be approved as
specified in item 7-2. |
|
6-3 |
High
temperature exposure test |
Temperature: 80±2°C
Time: 96hrs
|
|
6-4 |
High
humidity exposure test |
Temperature:
40±2°C
Humidity: 85~95% RH
Exposure time: 96hrs
No condensation of moisture |
|
6-5
|
Vibration test
|
Displacement: 3
mm, 100cpm
Frequency: 10 to 55 Hz
Period:
20 Minutes log sweep (10~55~10 Hz)
Direction: x, y, z
Time: Each 2 hours |
After the test motors shall be approved as
specified in item 7-2. |
|
6-6
|
Free Fall |
Test
state: Set the motor to the approximately 100g
(include the motor) weight of block drop the motor
on the concrete floor.
Height: 1.5 meters
Direction: ±x, ±y, ±z
Number of times: Twice each
|
After the test motors shall be approved as
specified in item 7-2. |
|
6-7
|
Heat
stock |
Circulate Condition:3 V voltage
2s ON, 1s OFF
Time: 2 Times |
After the test motors shall be approved as
specified in item 7-2. |
7. Requirements
|
Items
|
Requirements |
|
7-1 |
Table A |
1) Rated speed: Initial
data -30% min./ +60% max.
2) Rated current: Initial
data ±30% max
3) Insulation resistance: 10 MΩ min
4) Starting voltage: 1.5V DC
max
5) Current
waveform: Normal
|
|
7-2 |
Table B |
1) Rated speed: Initial
data -30% min./ +60% max.
2) Rated current: Initial
data ±30% max
3) Starting voltage: 1.5 V DC
max |
8. Matters to be paid attention
to when using motor
8-1 Lay the motors carefully in transportation to
avoid any damage to the motor body or its electric
function because of collision.
8-2 Storage temperature: 20±10°C. Do not leave
the motors in the environment of high temperature,
high humidity and gas that will cause rust and
corrosion. Do not store the motors for over 6
months.
8-3 Please do not lock the motor shaft when the
electric power is supplied.
8-4 Please do not touch the weights when motor is
rotating. |
|