1. General scope
1-1 The specifications apply
to the coreless cylindrical permanent magnetic micro vibration motor
DC model
Z4SH3B0030841.
2. Operating conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
2-1
|
Rated voltage
|
3.0V DC
|
|
|
2-2
|
Rated load
|
Counter weight
|
As specified in the outline
drawing.
|
|
2-3
|
Rated speed
|
C.W. ( Clockwise ) |
|
|
2-4
|
Motor position
|
All positions
|
|
|
2-5
|
Operating voltage
|
2.2~3.6V
DC
|
|
|
2-6
|
Operating conditions
|
-30 ~ 70°C, ordinary humidity
|
No condensation of moisture.
|
|
2-7 |
Storage conditions
|
-40 ~ 80°C, ordinary humidity
|
No condensation of moisture. |
3. Measuring conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63 ~ 67%) RH
|
|
|
3-3
|
Motor position
|
Shaft horizontal
|
Lock the motor in a test fixture.
|
3-4 All data are based on the measuring conditions: Temperature, 20°C;
Humidity, 65% RH. If any disagreement occurs, such test conditions are
available: Temperature, 5~35°C; Humidity, 45 ~ 85% RH.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition & Remarks
|
|
4-1
|
Configuration
|
As specified in outline drawing
|
Outline drawing No:Z4SH3B0030841.
|
|
4-2
|
Appearance
|
There shall be no evidence of
mechanical damage and shall not have inadequate corrosion, etc.
|
Visual examination: Inspection
carried out on samples.
|
|
4-3
|
Shaft end play
|
0.05 ~ 0.2mm
|
|
|
4-4
|
Weight of motor
|
1.11g approx.
|
Body + Vibration weight:
0.73+0.51
|
|
4-5
|
Holding strength of vibration
weight
|
49N (5kgf)
|
|
5. Performance and characteristics
|
Items
|
Specifications
|
Condition & Remarks
|
|
5-1
|
Rated speed
|
9,500±2000rpm
|
At rated voltage and rated load
(vibration weight).
|
|
5-2
|
Rated current
|
75mA
max
|
|
5-3
|
Stall current
|
90mA
max
|
At rated voltage.
|
|
5-4
|
Starting voltage
|
1.7V DC max
|
At rated load (vibration weight)
any position of rotor.
|
|
5-5
|
Insulation resistance
|
1MΩ min
|
At DC 100V between the lead wires
and motor body.
|
|
5-6
|
Terminal resistance
|
41Ω approx.
|
At 20°C.
|
|
5-7
|
Mechanical noise
|
50db (A) max
|
|
|
Measured at rated voltage and rated load (vibration weight).
Background noise: 28db (A) max. @ 10cm.
Measuring instruments: B & K.
The weight of jig: 700g.
|
|
 |
6. Reliability Test
|
Items
|
Standard test
conditions |
Condition &
Remarks |
|
6-1 |
Life test |
 |
After 2 hours exposure in
ordinary Motors shall be approved as specified in item 7-1. |
|
Position |
Voltage |
Load |
Temperature |
Humidity |
Life |
|
Horizontal |
Rated |
Counter weight |
20
ºC |
65 % |
200,000 cycles |
|
40
ºC |
9 0
% |
40,000 cycles |
|
|
6-2 |
Low temperature exposure
test |
Temperature: -40±2°C
Time:
96hrs
|
After the test motors
shall be approved as specified in item 7-2. |
|
6-3 |
High temperature exposure
test |
Temperature: 80±2°C
Time:
96hrs
|
|
6-4 |
High humidity exposure
test
|
Temperature: 40±2°C
Humidity:
96 ~ 95% RH
Exposure time: 96hrs
Dry time:
4hrs
No condensation of
moisture
|
|
6-5 |
Vibration test
|
Displacement: 1.5mm
(p-p)
Frequency: 10 ~ 55Hz
Period: 20
Mins log sweep
(10
~ 55 ~ 10Hz)
Direction: x, y,
z
Time: Every
2 hours |
After the test motors
shall be approved as specified in item 7-2. |
|
6-6 |
Free Fall |
Test state: Set the motor to the approximately 100 g
(include the motor) weight of block drop the motor on the concrete
floor.
Height: 1.5
meters
Direction: ±x,
±y, ±z
Times:
Twice each |
After the test motors
shall be approved as specified in item 7-2. |
|
6-7
|
Heat stock |
Test cycle: 5 cycles
 |
After the test motors shall be
approved as specified in item 7-2.
|
7.
Post environmental
|
Items |
Requirements
|
|
7-1
|
Table A
|
1) Rated
speed: Initial data -30% min./ +60% max.
2) Rated
current: Initial data ±30% max
3)
Insulation resistance: 1MΩ min
4) Starting
voltage:
2.0V DC max
5) Wave of
current: No blot wave. |
|
7-2
|
Table B
|
1) Rated
speed: Initial data -30% min./ +60% max.
2) Rated
current: Initial data ±30% max
3) Starting
voltage: 2.0V DC max |
8. Matters to be paid attention to when using motor
8-1 Lay the motors carefully in transportation to avoid any damage
to the motor body or its electric function because of collision.
8-2 Storage temperature: 20±10°. Do not leave the motors in the
environment of high temperature, high humidity and gas that will cause
rust and corrosion. Do not store the motors for over 6 months.
8-3 Do not lock the motor shaft when the electric power is
supplied.
8-4 Do not touch the weights when motor is rotating. |
|