2. Operating
condition
|
Item |
Specification |
|
2-1 |
Rated voltage |
3.0 V DC |
|
2-2 |
Operating voltage |
2.5~4.0
V DC |
|
2-3 |
Rotation |
CW(clockwise) or
CCW(contrary clockwise) |
|
2-4 |
Operating environment |
-20°C
~+60°C
,Ordinary Humidity |
|
2-5 |
Storage environment |
-30°C
~+70°C
,Ordinary Humidity |
3.
Test condition
|
Item
|
Specification
|
Conditions
|
|
3-1
|
Temperature
|
25±3°C
|
|
3-2
|
Humidity
|
65±20% RH
|
|
3-3
|
Power supply
|
DC power supply or battery 3.0V
|
4. Electrical initial characteristics
|
Item |
Specification |
Condition |
|
4-1 |
Rated speed |
10,000rpm Min |
At rated voltage |
|
4-2 |
Rated current |
90 mA Max |
At rated voltage |
|
4-3 |
Starting current |
120 mA Max |
At rated voltage |
|
4-4 |
Starting voltage |
2.3 V DC Max |
Motor is
rotating at min starting voltage. |
|
4-5 |
Insulation resistance |
10 MΩ Min |
At DC
100 V between lead wire and case. |
5. Mechanical characteristics
|
Item |
Specification |
|
5-1 |
Bracket deflection strength |
9.8 N or more |
|
5-2 |
Mechanical noise |
50 dB(A)Max |
|
At rated voltage,
back ground noise 28dB(A) Max |
 |
6.
Durability characteristics
|
Item
|
Specification
|
Requirements
|
|
6-1
|
Lifetime
|
Test cycle 50,000
cycles

|
After
the test, motors shall be approved as specified in item 7-1.
|
|
6-2
|
Low
temperature exposure
|
Temperature : -30°C
Time
: 96 h
|
After 4 hours exposure in ordinary
temperature and humidity, motors shall be approved as specified in item
7-2.
|
|
6-3
|
High
temperature exposure
|
Temperature : +70°C
Time
: 96 h
|
|
|
6-4
|
Humidity exposure
|
Temperature : +40°C
Humidity
: 95%RH
Exposure time : 96 h
No condensation of moisture
|
After 4 hours exposure in ordinary temperature and humidity, Motors shall
be approved as specified in item 7-2.
|
|
6-5
|
Vibration
|
Frequency:
10~55Hz
Acceleration:
22m/s2
Period: 10 Minutes log sweep
(10~55~10Hz)
Condition : This motion shall be applied for a period of
10 minutes in each of 3 mutually perpendicular axes.
|
After
the test motors shall be approved as specified in item 7-2.
|
|
6-6
|
Free fall
|
Test state: Set the motor to the approximately 100 g (include the motor)
weight of block drop the motor on the concrete floor.
Height :1.5 m
Direction : ±x, ±y, ±z
Number of times: Each 3 times
Shock : 29,420 N m/s2 Equivalent (3,000 G)
|
After
the test motors shall be approved as specified in item 7-2.
|
|
6-7
|
Heat stock test
|

Test cycle: 15 cycles.
|
After
the test motors shall be approved as specified in item 7-2.
|
7.
Requirements
|
Item |
Requirements |
|
7-1 |
Table A |
1)
Rated speed: Initial data-30 % Min/ Initial data+50 % Max
2) Rated current: Initial data-30 % Min/ Initial data+50
% Max
3)
Starting voltage: 2.5 V DC Max
4)
Insulation resistance: 10 MΩ Min |
|
7-2 |
Table B |
1) Rated speed: Initial data±20 % Max
2) Rated current: Initial data±20 % Max
3) Starting voltage: 2.5 V DC Max
|
8. Caution for Use
8-1 Unless it is used in accordance with the specifications ,the performance and
life may be considerably reduced . Due attention should be paid to voltage and
range for use .8-2 Avoid use the motor in the following environment.
8-2 Avoid use or save the motor in the following environment.
- High temperature and high humidity area.
- Corrosive gas such as H2S、SO2、NO2、Cl2.
- Dusty area.
8-3 Due attention must be paid to the handling and working environments because
such objects as iron powder if attracted by the motor maganent, will cause
noise, characteristic deterioration thus reducing the reliability.
8-4 Please confirm enough no problem of standards and laws and ordinances on
your cellular.
8-5 To handle the motor ,hold the motor case softly.
8-6 Rust of plate (steel) and similar edge should be OK.
8-7 Because there is error of the measurement equipment, permit the standard of
the rotational frequency to ±5 %.