VibratorMotor.com

VibratorMotor.com

Home     |     Product Info    |     About us     |     Factory tour     |    ISO Certifications    |    RoHS Info    |    Sample Request    |    Contact us   

 

                                                            Part No.    C1026B200F

           Click to Download PDF Format !

 

 

 

 

 

 

 

1.  Application

       This specification applies to flat permanent-magnetic motors DC model C1026B200F.

 

2.  Operating condition

Item

Specification

2-1

Rated voltage

3.0 V DC

2-2

Operating voltage

2.5~4.0 V DC

2-3

Rotation

CW(clockwise) or CCW(counter clockwise)

2-4

Operating environment

-20°C ~+60°C ,Ordinary Humidity

2-5

Storage environment

-30°C ~+70°C ,Ordinary Humidity

 

3.  Test condition

Item

Specification

Conditions

3-1

Temperature

25±3°C

3-2

Humidity

65±20% RH

3-3

Power supply

DC power supply or battery 3.0V

 

4.  Electrical initial characteristics

Item

Specification

Condition

4-1

Rated speed

10,000rpm Min

At rated voltage

4-2

Rated current

90 mA Max

At rated voltage

4-3

Starting current

120 mA Max

At rated voltage

4-4

Starting voltage

2.3 V DC Max

Motor is rotating at min starting voltage.

4-5

Insulation resistance

10 MΩ Min

At DC 100 V between lead wire and case.

 

5.  Mechanical characteristics

Item

Specification

5-1

Bracket deflection strength

9.8 N or more

5-2

Mechanical noise

50 dB(A)Max

At rated voltage, back ground noise 28dB(A) Max

 

 

6.       Durability characteristics

Item

Specification

Requirements

6-1

Lifetime

           Test cycle 50,000 cycles

After the test, motors shall be approved as specified in item 7-1.

6-2

Low temperature exposure

Temperature : -30°C

Time        : 96 h

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified in item 7-2.

6-3

High temperature exposure

Temperature : +70°C

Time        : 96 h

 

6-4

Humidity exposure

Temperature : +40°C

Humidity    : 95%RH

Exposure time : 96 h   

No condensation of moisture

After 4 hours exposure in ordinary temperature and humidity, Motors shall be approved as specified in item 7-2. 

6-5

Vibration

Frequency:        10~55Hz

Acceleration:      22m/s2

Period: 10 Minutes log sweep

             (10~55~10Hz)

Condition    : This motion shall be applied for a period of 10 minutes in each of 3 mutually perpendicular axes.

After the test motors shall be approved as specified in item 7-2.

6-6

Free fall

Test state: Set the motor to the approximately 100 g (include the motor) weight of block drop the motor on the concrete floor.

Height        :1.5 m

Direction     : ±x, ±y, ±z

Number of times: Each 3 times

Shock : 29,420 N m/s2 Equivalent (3,000 G)

After the test motors shall be approved as specified in item 7-2.

6-7

Heat stock test

     

 

Test cycle: 15 cycles.

After the test motors shall be approved as specified in item 7-2.

 

7.    Requirements

Item

Requirements

7-1

Table A

1) Rated speed:       Initial data-30 % Min/ Initial data+50 % Max

2) Rated current:     Initial data-30 % Min/ Initial data+50 % Max

3) Starting voltage:                     2.5 V DC Max

4) Insulation resistance: 10 MΩ Min

7-2

Table B

1) Rated speed:                Initial data±20 % Max

2) Rated current:              Initial data±20 % Max

3) Starting voltage:          2.5 V DC Max

 

8.   Caution for Use

8-1 Unless it is used in accordance with the specifications, the performance and life may be considerably reduced . Due attention should be paid to voltage and range for use.

8-2 Avoid use or save the motor in the following environment.

- High temperature and high humidity area.

- Corrosive gas such as H2SSO2NO2Cl2.

- Dusty area.

8-3 Due attention must be paid to the handling and working environments because such objects as iron powder if attracted by the motor magnet , will cause noise, characteristic deterioration thus reducing the reliability.

8-4 Please confirm enough no problem of standards and laws and ordinances on your cellular.

8-5 To handle the motor ,hold the motor case softly.

8-6 Rust of plate (steel) and similar edge should be OK.

8-7 Because there is error of the measurement equipment, permit the standard of the rotational frequency to ±5 .