1.
General scope
1-1
The
specifications apply to the coreless cylindrical permanent
magnetic micro vibration motor DC model
6SL1-06WA.
2. Operating conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
2-1
|
Rated voltage
|
1.3V DC
|
|
|
2-2
|
Rated load
|
Counterweight
|
As specified in the outline
drawing.
|
|
2-3
|
Rated speed
|
8500±2000rpm
|
|
|
2-4
|
Rotation
|
C.W. (clockwise)
|
|
|
2-5
|
Motor position
|
All positions
|
|
|
2-6
|
Operating voltage
|
0.9 ~ 1.6V DC
|
|
|
2-7
|
Operating conditions
|
-30 ~ 70°C, ordinary
humidity
|
No condensation of moisture.
|
|
2-8
|
Storage conditions
|
-40 ~ 80°C, ordinary
humidity
|
No condensation of moisture.
|
3.
Measuring conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63 ~ 67%) RH
|
|
|
3-3
|
Motor position
|
Shaft horizontal
|
Lock the motor in a test
fixture.
|
All data are
based on the measuring conditions: Temperature, 20°C and
Humidity, 65% RH.
However, the ranges of temperature
5~35°C
and humidity 45~85 %RH are to be applicable as long as no
problems.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition & Remarks
|
|
4-1
|
Configuration
|
As specified in outline
drawing
|
Outline drawing No:
6SL1-06WA.
|
|
4-2
|
Appearance
|
There shall be no evidence
of mechanical damage and shall not have inadequate
corrosion, etc.
|
Visual examination:
Inspection carried out on samples.
|
|
4-3
|
Shaft end play
|
0.1 ~ 0.3mm
|
|
|
4-4
|
Weight of motor
|
5.52
g approx.
|
|
|
4-5
|
Holding strength of
vibration weight
|
49N (5kgf)
|
|
5.
Performance and characteristics
|
Items
|
Specifications
|
Condition & Remarks
|
|
5-1
|
Rated speed
|
8500±2000rpm
|
At rated voltage and rated
load (vibration weight).
|
|
5-2
|
Rated current
|
90mA
max
|
|
5-3
|
Stall current
|
145mA max
|
At rated voltage.
|
|
5-4
|
Starting voltage
|
0.75V DC max
|
At rated load (vibration
weight) any position of rotor.
|
|
5-5
|
Insulation resistance
|
1MΩ min
|
At DC 100V between the lead
wires and motor body.
|
|
5-6
|
Terminal resistance
|
11
Ω
approx.
|
At 20°C.
|
|
5-7
|
Mechanical noise
|
50db (A) max
|
|
|
At rated voltage and rated
load (counterweight).
Back ground noise 28 db (A) max.
Measuring instruments: B & K
Weight of jig: 700 g
 |
6.
Reliability Test
|
Items
|
Standard test conditions
|
Condition & Remarks
|
|
6-1
|
Life test
|
 |
After 2 hours exposure in
ordinary Motors shall be approved as specified in item
7-1.
|
|
Position |
Voltage |
Load |
Temperature |
Humidity |
Life |
|
Horizontal |
Rated |
Counter weight |
20 ºC |
65 % |
200,000 cycles |
|
40 ºC |
90 % |
40,000 cycles |
|
|
6-2
|
Low temperature |
Temperature: -40±2°C
Time: 96hrs
|
After 2 hours exposure in
ordinary Motors shall be approved as specified in item
7-2.
|
|
6-3
|
High temperature
|
Temperature: 60±2°C
Time:
96hrs
|
|
6-4
|
High humidity exposure test
|
Temperature: 40±2°C
Humidity:
90 ~ 95% RH
Exposure time: 96hrs
Dry time:
4hrs
No condensation of moisture
|
|
6-5
|
Vibration test
|
Displacement: 1.5mm
(p-p)
Frequency: 10 ~ 55Hz
Period: 20 Mins
log sweep
(10 ~ 55 ~ 10Hz)
Direction: x, y, z
Time: Every 2
hours
|
After the test motors shall
be approved as specified in item 7-2.
|
|
6-6
|
Free fall |
Test state: Set the motor to
the approximately 100 g (include the motor) weight of
block drop the motor on the concrete floor.
Height: 1.5 m
Direction: ±x, ±y, ±z
Number of times: Twice each |
After the test motors shall
be approved as specified in item 7-2.
|
|
6-7
|
Heat stock |

|
Period:32
Exposed at ordinary
temperature and ordinary humidity for 24 hours
before measurement |
|
After the test motors shall
be approved as specified in item 7-2.
|
7.
Post environmental
|
Items
|
Requirements
|
|
7-1
|
Table A
|
1) Rated speed: Initial
data -30 % min.; Initial data +60 % max.
2) Rated current: Initial data ±30 % max.
3) Insulation resistance: 1 MΩ min.
4) Starting voltage: 1.1 V DC max.
5) Current waveform: Normal |
|
7-2
|
Table B
|
1) Rated speed: Initial
data -30 % min.; Initial data +60 % max.
2) Rated current: Initial data ±30 % max.
3) Starting voltage: 1.1 V DC max. |
|
8. Matters to be paid
attention to when using motor
8-1 Please lay the motors carefully in transportation to
avoid any damage to the motor body or its electric
function because of collision.
8-2 Please do not leave the motors in the environment of
high temperature, high humidity and gas that will cause
rust and corrosion. Please don’t store the motors for over
6 months.
8-3 Please do not lock the motor shaft when the electric
power is supplied.
8-4 Please do not touch the weights when motor is
rotating. |
|