1.
General scope
1-1
The specifications apply to the coreless cylindrical
permanent magnetic micro vibration motor DC model
Z6SC0B0170081.
2. Operating
conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
2-1
|
Rated voltage
|
3.0V
DC
|
|
|
2-2
|
Rated load
|
Vibration weight
|
As specified in the outline drawing.
|
|
2-3
|
Rated speed
|
8000±2000rpm
|
|
|
2-4
|
Rotation
|
C.W. (clockwise)
|
|
|
2-5
|
Motor position
|
All positions
|
|
|
2-6
|
Operating voltage
|
2.0
~ 3.8 V DC
|
|
|
2-7
|
Operating conditions
|
-30 ~ 70°C, ordinary humidity
|
No condensation of moisture.
|
|
2-8
|
Storage conditions
|
-40 ~ 80°C, ordinary humidity
|
No condensation of moisture.
|
3.
Measuring conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63 ~ 67%) RH
|
|
|
3-3
|
Motor position
|
Shaft horizontal
|
Lock the motor in a test fixture.
|
3-4 All data are based on
the measuring conditions: Temperature, 20°C; Humidity, 65% RH. If any
disagreement occurs, such test conditions are available: Temperature,
5~35°C; Humidity, 45 ~ 85% RH.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition & Remarks
|
|
4-1
|
Configuration
|
As specified in outline drawing
|
Outline drawing No:
Z6SC0B0170081.
|
|
4-2
|
Appearance
|
There shall be no evidence of mechanical
damage and shall not have inadequate corrosion, etc.
|
Visual examination: Inspection carried out
on samples.
|
|
4-3
|
Shaft end play
|
0.1 ~ 0.3mm
|
|
|
4-4
|
Weight of motor
|
2.5g approx.
|
|
|
4-5
|
Holding strength of vibration weight
|
49N (5kgf)
|
|
5.
Performance and characteristics
|
Items
|
Specifications
|
Condition & Remarks
|
|
5-1
|
Rated speed
|
8000±2500rpm
|
At rated voltage and rated load (vibration
weight).
|
|
5-2
|
Rated current
|
70mA max
|
|
5-3
|
Stall current
|
100mA max
|
At rated voltage.
|
|
5-4
|
Starting voltage
|
1.7
V DC max
|
At rated load (vibration weight) any
position of rotor.
|
|
5-5
|
Insulation resistance
|
1MΩ min
|
At DC 100V between the lead wires and
motor body.
|
|
5-6
|
Terminal resistance
|
1Ω approx.
|
At 20°C.
|
|
5-7
|
Mechanical noise
|
35db (A) max
|
|
|
Measured at rated voltage and rated load
(Counterweight).
Background noise: 28db (A) max.
Measuring instruments: B & K.
The weight of jig: 700g.

|
6. Reliability Test
|
Items
|
Standard test conditions
|
Condition & Remarks
|
|
6-1
|
Life test
|

|
After 2 hours exposure in ordinary Motors
shall be approved as specified in item 7-1.
|
|
Position |
Voltage |
Load |
Temperature |
Humidity |
Life |
|
Horizontal |
Rated |
Counter weight |
20 ºC
|
65 % |
200,000 cycles |
|
40 ºC |
90 % |
40,000 cycles |
|
|
6-2
|
Low temperature exposure test
|
Temperature: -40±2°C
Time: 96 hrs
|
After 2 hours exposure in ordinary Motors
shall be approved as specified in item 7-2.
|
|
6-3
|
High temperature exposure test
|
Temperature: 60±2°C
Time: 96 hrs
|
|
6-4
|
High humidity exposure test
|
Temperature: 40±2°C
Humidity: 90 ~ 95% RH
Exposure time: 96hrs
Dry time: 4hrs
No condensation of
moisture
|
|
6-5
|
Vibration test
|
Displacement: 1.5mm (p-p)
Frequency: 10 ~ 55Hz
Period: 20 Mins log sweep (10
~ 55 ~ 10Hz)
Direction: x, y, z
Time: Every 2 hours
|
After the test motors shall be approved as
specified in item 7-2.
|
|
6-6
|
Drop test
|
Test state: Set the motor to the
approximately 75 g (include the motor) weight of block drop the motor on
the concrete floor.
Height: 1.5 m
Direction: ±x, ±y, ±z
Number of times: Twice each |
After the test motors shall be approved as
specified in item 7-2.
|
|
6-7
|
Heat stock test
|
 |
After the test motors shall be approved as
specified in item 7-2.
|
7. Post environmental
|
Items
|
Requirements
|
|
7-1
|
Table A
|
1) Rated speed: Initial data
-30 % min.; Initial data +60 % max.
2) Rated current: Initial data ±30 % max.
3) Insulation resistance: 1 MΩ min.
4) Starting voltage: 1.7 V DC max.
5) Current waveform: Normal |
|
7-2
|
Table B
|
1) Rated speed: Initial data -30 % min.;
Initial data +60 % max.
2) Rated current: Initial data ±30 % max.
3) Starting voltage: 1.7 V DC max. |
8.
Matters to be
paid attention to when using motor
8-1 Please lay the motors carefully in
transportation to avoid any damage to the motor body or its electric
function because of collision.
8-2 Please do not leave the motors in the
environment of high temperature, high humidity and gas that will cause rust
and corrosion. Please don’t store the motors for over 6 months.
8-3 Please do not lock the motor shaft when
the electric power is supplied.
8-4 Please do not touch the weights when motor
is rotating.
|